Oxygen and fuel gas pressure regulators, including their related gauges, shall be in proper working order while in use. Communications. Variations of one or two shade numbers are permissible to suit individual preferences. The hot work permit helps the permit authorizing individual, hot work operator, and fire watch recognize potential hazards. 1926.858 - Removal of steel construction. Workers, supervisors, fire wardens, and contractors should be trained specific to their roles. A copy of the contractor's written Hot Work Permit Procedures shall be available for EH&S review. 1926.11 - Coverage under section 103 of the act distinguished. 1926 Subpart CC App A - Standard Hand Signals, 1926 Subpart CC App B - Assembly/DisassemblySample Procedures for Minimizing the Risk of Unintended Dangerous Boom Movement, 1926 Subpart CC App C - Operator CertificationWritten ExaminationTechnical Knowledge Criteria, Severe Storm and Flood Recovery Assistance. 1926.1405 - Disassemblyadditional requirements for dismantling of booms and jibs (applies to both the use of manufacturer procedures and employer procedures). The valve of a fuel gas cylinder shall not be cracked where the gas would reach welding work, sparks, flame, or other possible sources of ignition. In flammable or potentially flammable atmospheres: On or in equipment or tanks that have contained flammable gas or liquid or combustible liquid or dust-producing material, until a designated person has tested the atmosphere inside the equipment or tanks and determined that it is not hazardous; or. The precautions that the host employer, controlling contractor, or other entry employers implemented for the protection of employees in the permit spaces. If testing and inspection during that entry demonstrate that the hazards within the permit space have been eliminated or isolated, the permit space may be reclassified as a non-permit confined space for as long as the hazards remain eliminated or isolated; The entry employer must document the basis for determining that all hazards in a permit space have been eliminated or isolated, through a certification that contains the date, the location of the space, and the signature of the person making the determination. Oxygen and fuel hoses shall not be interchangeable. A single hose having more than one gas passage shall not be used. 0000013465 00000 n Shall not have objects that might either damage the safety device or obstruct the valve placed on top of the cylinder when in use. 1926.854 - Removal of walls, masonry sections, and chimneys. 0000012747 00000 n Torches shall be lighted by friction lighters or other approved devices, and not by matches or from hot work. Arcs, sparks or heat at any point in the circuit shall cause rejection as a ground circuit. This section contains the required practices and procedures necessary to protect employees from fire and explosion hazards associated with hot work. Welding, cutting or heating of toxic metals. Oxygen shall not be used for ventilation, cooling or cleaning clothing or work areas. 0000007871 00000 n 1926.951 - Medical services and first aid. The entry employer must then reevaluate the space and reclassify it as a permit space as appropriate in accordance with all other applicable provisions of this standard. If the object to be welded or cut cannot readily be moved, all movable fire hazards in the vicinity shall be taken to a safe place. 1926.432 - Environmental deterioration of equipment. 1926.652 - Requirements for protective systems. (This action is generally termed "cracking" and is intended to clear the valve of dust or dirt that might otherwise enter the regulator.) When cylinders are hoisted, they shall be secured on a cradle, slingboard, or pallet. Surfaces covered with preservative coatings shall be stripped for at least 4 inches (10.16 cm) from the area of heat application or employees shall be protected by supplied air respirators in accordance with the requirements of 1910.134 of this chapter. 1926.860 - Selective demolition by explosives. Fuel gas hose and oxygen hose shall be easily distinguishable from each other. No one shall use a cylinder's contents for purposes other than those intended by the supplier. Valve protection caps shall not be used for lifting cylinders from one vertical position to another. 1926.350 Gas Welding and Cutting 1926.350 (a) Transporting, Moving, and Storing Compressed Gas Cylinders 1926.350 (a) (1) Valve protection caps shall be in place and secured. 0000001616 00000 n Confined spaces and permit spaces. Torches shall not be lighted from matches, cigarette lighters, other flames or hot work. 0000035922 00000 n 0000003987 00000 n 0000031614 00000 n )*@w>Hk'z&wjf6pM[OKo/!I:;jq:wicxLc;_Ka.\kS,0|;\KeO&)>W0upx!YeY[|I}Ug*uo/c[>/+ jMMM*YD2.Z=Vj %K2`.\Y+ %PDF-1.7 % Any special wrench required for emergency closing shall be positioned on the valve stem during cylinder use. 1926.704 - Requirements for precast concrete. Compressed gas cylinders shall be secured in an upright position at all times except, if necessary, for short periods of time while cylinders are actually being hoisted or carried. 1926.35 - Employee emergency action plans. 0000016958 00000 n hb`````P}AX8v00 x(dAn^>OM 5a&FAA@2 (h `@y mA`93N03d7(`pa8 TPj~!A2uWqV )2,[X{0=# If there is no controlling contractor present at the worksite, the requirements for, and role of, controlling contactors in this section must be fulfilled by the host employer or other employer who arranges to have employees of another employer perform work that involves permit space entry. 0000006757 00000 n Welding, cutting and heating (hot work)[12] (See also 1917.2, definition of Hazardous cargo, materials, substance, or atmosphere). Occupational Safety and Health Administration, Outreach Training Program (10- and 30-hour Cards), OSHA Training Institute Education Centers, Severe Storm and Flood Recovery Assistance. Except as specified in paragraphs (f)(3)(ii) and (f)(3)(iii) of this section, when hot work is performed in a confined space the employer shall ensure that: General mechanical or local exhaust ventilations shall be provided; or. The employer must verify that the space is safe for entry and that the preentry measures required by paragraph (e)(2) of this section have been taken, through a written certification that contains the date, the location of the space, and the signature of the person providing the certification. The employer shall ensure that general mechanical ventilation or local exhaust systems shall meet the following requirements: General mechanical ventilation shall maintain vapors, fumes and smoke below a hazardous level. 1926.1406 - Assembly/Disassemblyemployer procedures--general requirements. Oxygen and fuel gas hoses shall not be interchangeable. Continuous forced air ventilation must be used, as follows: An employee must not enter the space until the forced air ventilation has eliminated any hazardous atmosphere; The forced air ventilation must be so directed as to ventilate the immediate areas where an employee is or will be present within the space and must continue until all employees have left the space; The air supply for the forced air ventilation must be from a clean source and must not increase the hazards in the space. Permit space entry is performed at the same time that any activities that could foreseeably result in a hazard in the permit space are performed. 0000010051 00000 n Yes, permits for performing hot work are required by both OSHA and the National Fire Protection Association (NFPA), in addition to the local fire code. The employer must ensure a safe method of entering and exiting the space. [48 FR 30909, July 5, 1983; 62 FR 40141, July 25, 1997; 65 FR 40942, June 30, 2000], Occupational Safety & Health Administration. 1926.703 - Requirements for cast-in-place Concrete. 1926.606 - Definitions applicable to this subpart. Suitable fire extinguishing equipment shall be immediately available in the work area and shall be maintained in a state of readiness for instant use. 1926 Subpart O - Motor Vehicles, Mechanized Equipment, and Marine Operations. 1926.702 - Requirements for equipment and tools. 1926.60 App A - Substance Data Sheet, for 4-4'-METHYLENEDIANILINE, 1926.60 App B - Substance Technical Guidelines, MDA, 1926.60 App C - Medical Surveillance Guidelines for MDA, 1926.60 App D - Sampling and Analytical Methods for MDA Monitoring and Measurement Procedures. Structures or pipelines acting continuously as ground return circuits shall have joints bonded and maintained to ensure that no electrolysis or fire hazard exists. Inert-gas metal-arc welding. Pressure regulators, including associated gauges, shall be maintained in safe working order. Torches with such defects shall not be used. Manifold hose connections, including both ends of the supply hose that lead to the manifold, shall be such that the hose cannot be interchanged between fuel gas and oxygen manifolds and supply header connections. 1929 wheat penny. Where required by your AHJ, use this fillable PDF form to complete and submit your AHJ Hot Work Permit application electronically - saves time printing and scanning! 1926 Subpart F - Fire Protection and Prevention. 1926.1208 - Duties of authorized entrants. Before entry operations begin, the controlling contractor must: Obtain the host employer's information about the permit space hazards and previous entry operations; and. Getting a hot work permit before performing hot work is just one of steps involved in a hot work . Hose subjected to flashback or showing evidence of severe wear or damage shall be tested to twice the normal working pressure but not less than 200 p.s.i. 1926.1428 - Signal person qualifications. 1926.152 Flammable liquids. 0000065789 00000 n Cylinders, cylinder caps and valves, couplings, regulators, hose, and apparatus shall be kept free from oil or greasy substances and shall not be handled with oily hands or gloves. 1926.55 - Gases, vapors, fumes, dusts, and mists. the required city permits, when necessary, for such work. 1926.1410 - Power line safety (all voltages)equipment operations closer than the Table A zone. Cylinders shall be kept far enough away from the actual welding or cutting operation so that sparks, hot slag, or flame will not reach them. Before heat is applied to a drum, container or hollow structure, an opening to release built-up pressure during heat application shall be provided. Arc welding and cutting cables shall be insulated, flexible and capable of handling the maximum current required by the operations, taking into account the duty cycles. hot work hazards and control measures pdf. For the elimination of possible fire in enclosed spaces as a result of gas escaping through leaking or improperly closed torch valves, the gas supply to the torch shall be positively shut off at some point outside the enclosed space whenever the torch is not to be used or whenever the torch is left unattended for a substantial period of time, such as during the lunch period. 1926.107 - Definitions applicable to this subpart. The control apparatus of arc welding machines shall be enclosed, except for operating wheels, levers, and handles. 1926 Subpart CC - Cranes and Derricks in Construction. Fuel gas and oxygen manifolds shall bear the name of the substance they contain in letters at least 1-inch high which shall be either painted on the manifold or on a sign permanently attached to it. When oxygen and fuel gas hoses are taped together, not more than four (4) of each 12 inches (10.16 cm of each 30.48 cm) shall be taped. INTRODUCTION . Empty containers shall be removed to a safe area apart from hot work operations or open flames. 1926.651 - Specific Excavation Requirements. Permits usu-ally are valid only for the length of the working shift; but never more than 24 hours. 1926 Subpart L App C - List of National Consensus Standards. An employer whose employees enter a permit space need not comply with 1926.1204 through 1206 and 1926.1208 through 1211, provided that all of the following conditions are met: The employer can demonstrate that all physical hazards in the space are eliminated or isolated through engineering controls so that the only hazard posed by the permit space is an actual or potential hazardous atmosphere; The employer can demonstrate that continuous forced air ventilation alone is sufficient to maintain that permit space safe for entry, and that, in the event the ventilation system stops working, entrants can exit the space safely; The employer develops monitoring and inspection data that supports the demonstrations required by paragraphs (e)(1)(i) and (ii) of this section; If an initial entry of the permit space is necessary to obtain the data required by paragraph (e)(1)(iii) of this section, the entry is performed in compliance with 1926.1204 through 1926.1211; The determinations and supporting data required by paragraphs (e)(1)(i), (ii), and (iii) of this section are documented by the employer and are made available to each employee who enters the permit space under the terms of paragraph (e) of this section or to that employee's authorized representative; and. 29 CFR 1904.0. Hose shall be inspected before use. Fuel gas shall not be used from cylinders through torches or other devices which are equipped with shutoff valves without reducing the pressure through a suitable regulator attached to the cylinder valve or manifold. 1926 Subpart L App D - List of Training Topics for Scaffold Erectors and Dismantlers. Definition. The following requirements apply to entry into permit spaces that meet the conditions set forth in paragraph (e)(1) of this section: Any conditions making it unsafe to remove an entrance cover must be eliminated before the cover is removed. 1926.449 - Definitions applicable to this subpart. Use of fuel gas. Shut down all operation if you discover a fire hazard without a fire watch. 1926 Subpart L App E - Drawings and Illustrations. 0000041672 00000 n Occupational Safety & Health Administration, Occupational Safety and Health Administration, Outreach Training Program (10- and 30-hour Cards), OSHA Training Institute Education Centers. Open end fuel gas and oxygen hoses shall be immediately removed from enclosed spaces when they are disconnected from the torch or other gas-consuming device. Lou, Paris 11eme, recherche des personnes motives et comptentes qui partagent notre enthousiasme pour la gastronomie, le vin et l'hospitalit pour devenir Chef de Parties dans notre quipe . 0000054473 00000 n Use of fuel gas. |_W+B s&M07Any'hz)(QM/Q^F>cE>]co7 F~o7 F~o7W*UI J_YZhx3cJkCp{]~pq B* endstream endobj 81 0 obj <>stream Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior. They shall not be hoisted or transported by means of magnets or choker slings. Before entry operations begin, each entry employer must: Obtain all of the controlling contractor's information regarding permit space hazards and entry operations; and. Such personnel shall be instructed as to the specific anticipated fire hazards and how the firefighting equipment provided is to be used. 1926.452 - Additional requirements applicable to specific types of scaffolds. No welding, cutting, or heating shall be done where the application of flammable paints, or the presence of other flammable compounds, or heavy dust concentrations creates a hazard. Sharing policies. When welding, cutting, or heating is performed on walls, floors, and ceilings, since direct penetration of sparks or heat transfer may introduce a fire hazard to an adjacent area, the same precautions shall be taken on the opposite side as are taken on the side on which the welding is being performed. 1926.1427 - Operator training, certification, and evaluation. 1926.1213 - Provision of documents to Secretary. Nothing shall be placed on top of a cylinder or associated parts when the cylinder is in use. If continuous monitoring is used, the employer must ensure that the monitoring equipment has an alarm that will notify all entrants if a specified atmospheric threshold is achieved, or that an employee will check the monitor with sufficient frequency to ensure that entrants have adequate time to escape. 1926 Subpart H - Materials Handling, Storage, Use, and Disposal. Here's a condensed version: Monitor all hot work in your facility. Occupational Safety and Health Administration, Outreach Training Program (10- and 30-hour Cards), OSHA Training Institute Education Centers, Severe Storm and Flood Recovery Assistance, Inert-gas Metal-Arc Welding (Non-ferrous) 1/16- to 5/32-inch electrodes. English 02/23/2023. The certification must be made available to each employee entering the space or to that employee's authorized representative; and. 1926.1419 - Signalsgeneral requirements. Hot electrode holders shall not be dipped in water. Hot Work Procedures and Permits (a) Scope and application. Employees in the space shall wear supplied air respirators in accordance with 1910.134 and a standby on the outside shall maintain communication with employees inside the space and shall be equipped and prepared to provide emergency aid. Expanding on OSHA's definition, hot work means welding, brazing, cutting, soldering, thawing pipes, using heat guns, torch applied roofing and chipping operations, or the use of spark . 1926.955 - Portable ladders and platforms. Exposed metal parts shall be insulated. a. OSHA amended 29 CFR Part 1960 to implement its "Multi-Employer Worksite Policy" in the federal sector, as stated in 60 Federal Register (FR) 35040. 0000025889 00000 n 1926.964 - Overhead lines and live-line barehand work. A hot work permit is a legal requirement in certain areas or job sites that gives workers or contractors the authorization to proceed with hot work activities. 1926.1205 (c) Fill in the necessary boxes that are colored in yellow. When there are changes in the use or configuration of a non-permit confined space that might increase the hazards to entrants, or some indication that the initial evaluation of the space may not have been adequate, each entry employer must have a competent person reevaluate that space and, if necessary, reclassify it as a permit-required confined space. When electrode holders are left unattended, electrodes shall be removed and holders placed to prevent employee injury. 1926.552 - Material hoists, personnel hoists, and elevators. Where practicable all combustibles shall be relocated at least 35 feet from the work site. Note to paragraph (h). Hose which has been subject to flashback, or which shows evidence of severe wear or damage, shall be tested to twice the normal pressure to which it is subject, but in no case less than 300 p.s.i. 1926.903 - Underground transportation of explosives. 0000048630 00000 n Beyond that, look for fire hazards across the entire workplace. Employees exposed to radiation shall have their skin covered completely to prevent ultraviolet burns and damage. When openings or cracks in flooring cannot be closed, precautions shall be taken to ensure that no employees or flammable or combustible materials on the floor below are exposed to sparks dropping through the floor. U |`" endstream endobj 68 0 obj <>>> endobj 69 0 obj <> endobj 70 0 obj >/PageUIDList<0 247>>/PageWidthList<0 612.0>>>>>>/Resources<>/ExtGState<>/Font<>/ProcSet[/PDF/Text/ImageC]/Properties<>/XObject<>>>/Rotate 0/Tabs/W/Thumb 62 0 R/TrimBox[0.0 0.0 612.0 792.0]/Type/Page>> endobj 71 0 obj <> endobj 72 0 obj <> endobj 73 0 obj <> endobj 74 0 obj <> endobj 75 0 obj <> endobj 76 0 obj <> endobj 77 0 obj <>stream hot work have been covered with a wet rag. When practical, objects to be welded, cut, or heated shall be moved to a designated safe location or, if the objects to be welded, cut, or heated cannot be readily moved, all movable fire hazards in the vicinity shall be taken to a safe place, or otherwise protected. "Hot work" means riveting, welding, flame cutting or other fire or spark-producing operation. 0000053217 00000 n Employees shall not engage in and shall not be exposed to the inert-gas metal-arc welding process unless the following precautions are taken: Chlorinated solvents shall not be used within 200 feet (61 m) of the exposed arc. Gas welding equipment shall be maintained free of oil and grease. 1926.962 - Grounding for the protection of employees. The controlling contractor must debrief each entity that entered a permit space regarding the permit space program followed and any hazards confronted or created in the permit space(s) during entry operations; The entry employer must inform the controlling contractor in a timely manner of the permit space program followed and of any hazards confronted or created in the permit space(s) during entry operations; and. When work is finished, when cylinders are empty, or when cylinders are moved at any time, the cylinder valve shall be closed. 1926.1408 - Power line safety (up to 350 kV)equipment operations. Occupational Safety and Health Administration, Outreach Training Program (10- and 30-hour Cards), OSHA Training Institute Education Centers, Severe Storm and Flood Recovery Assistance. California State University - San Marcos (CSUSM) is dedicated to the protection of our The entry permit that documents compliance with this section and authorizes entry to a permit space must identify: The date and the authorized duration of the entry permit; The authorized entrants within the permit space, by name or by such other means (for example, through the use of rosters or tracking systems) as will enable the attendant to determine quickly and accurately, for the duration of the permit, which authorized entrants are inside the permit space; The employer must implement measures to protect employees from the hazard before any subsequent entry takes place. When cylinders are transported by powered vehicles, they shall be secured in a vertical position. Expanding on OSHA's definition, hot work means welding, brazing, cutting, soldering, thawing pipes, using heat guns, torch applied roofing and chipping operations, or the use of spark . 1926.961 - Deenergizing lines and equipment for employee protection. 0000006146 00000 n Ask what a fire watch is. Cylinders shall be placed where they cannot become part of an electrical circuit. Sharing procedures. %\9 Working with ignition sources near flammable materials is referred to as "hot work." Welding, soldering and cutting are examples of hot work. Fire extinguishing equipment suitable for the location shall be immediately available and shall be maintained in readiness for use at all times. Valves shall not be cracked if gas could reach possible sources of ignition; Cylinder valves shall be opened slowly to prevent regulator damage and shall not be opened more than 1 turns. 6, 1979, as amended at 55 FR 42328, Oct. 18, 1990; 58 FR 35179, June 30, 1993], Occupational Safety & Health Administration. Assigned storage places shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cn|lv }9! Pressure-reducing regulators shall be attached to cylinder valves when cylinders are supplying torches or devices equipped with shut-off valves; Cylinder valves shall be closed and gas released from the regulator or manifold before regulators are removed; Leaking fuel gas cylinder valves shall be closed and the gland nut tightened. If the leak continues, the cylinder shall be tagged, removed from service, and moved to a location where the leak will not be hazardous. Assuming a hot work permit is required, it must be issued by a "Permit Authorizing Individual (PAI)." It is the responsibility of the department employing and supervising 1926 Subpart M App A - Determining Roof Widths - Non-mandatory Guidelines for Complying with 1926.501(b)(10), 1926 Subpart M App B - Guardrail Systems - Non-Mandatory Guidelines for Complying with 1926.502(b), 1926 Subpart M App C - Personal Fall Arrest Systems - Non-Mandatory Guidelines for Complying with 1926.502(d), 1926 Subpart M App D - Positioning Device Systems - Non-Mandatory Guidelines for Complying with 1926.502(e), 1926 Subpart M App E - Sample Fall Protection Plan - Non-Mandatory Guidelines for Complying with 1926.502(k), 1926 Subpart N - Helicopters, Hoists, Elevators, and Conveyors. Hot work. Pressure regulators. The California Code of Regulations (CCR), title 8, section 341 and section 341.1 require employers to obtain Project Permits and Annual Permits from Cal/OSHA before conducting certain construction activities. 0000014709 00000 n It is a written document filled out at the work site after a thorough review of the work to be completed and the work area. 1926.1153 - Respirable crystalline silica. 0000000016 00000 n 0000007213 00000 n 0000038376 00000 n 0000020682 00000 n 0000054149 00000 n Hose couplings shall not unlock or disconnect without rotary motion. +%o;F~w"W`OJMRSgMUUfTdTfTdTfTd+0W@@?~ +?cz0^mo)i*_ *x endstream endobj 78 0 obj <> endobj 79 0 obj [/ICCBased 108 0 R] endobj 80 0 obj <>stream Defective hose shall be removed from service. When the welding, cutting, or heating operation is such that normal fire prevention precautions are not sufficient, additional personnel shall be assigned to guard against fire while the actual welding, cutting, or heating operation is being performed, and for a sufficient period of time after completion of the work to ensure that no possibility of fire exists. 1926.251 - Rigging equipment for material handling. The basic precautions for fire prevention in welding or cutting work are: 1910.252 (a) (1) (i) Fire hazards. Insert the date. Oil and grease hazards. Torches shall be inspected before each use for leaking shut-off valves, hose couplings and tip connections. Filter lenses shall have an appropriate shade number, as indicated in Table G-1, for the work performed. 67 66 hot work training. Yann Wehrling, vice-prsident de la rgion le-de-France, charg de la Transition cologique, et Patrice Leclerc, maire de Gennevilliers et Prsident du groupe Front De Gauche la . C [^. If it is necessary to enter the permit space to eliminate or isolate hazards, such entry must be performed under 1926.1204 through 1926.1211. 0000052089 00000 n Before it begins work at a worksite, each employer must ensure that a competent person identifies all confined spaces in which one or more of the employees it directs may work, and identifies each space that is a permit space, through consideration and evaluation of the elements of that space, including testing as necessary. OSHA 29 CFR 1910.252 required fire prevention actions for welding/hot works. Get Form. 1926.1107 - 3,3'-Dichlorobenzidine (and its salts). Includes how employers must control respiratory hazards in the space; testing the internal atmosphere; and what to document for each entry. Before heat is applied to a drum, container, or hollow structure, a vent or opening shall be provided for the release of any built-up pressure during the application of heat. Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. 1926 Subpart R App F - Perimeter Columns: Non-Mandatory Guidelines for Complying with 1926.756(e) To Protect the Unprotected Side or Edge of a Walking/Working Surface. The following terms are defined for the purposes of this subpart only: Acceptable entry conditions means the conditions that must exist in a permit space, before an employee may enter that space, to ensure that employees can safely enter into, and safely work within, the space.. An uncoiled fire hose with fog nozzle, under pressure, shall be immediately available in the hot work area. Boxes used for the storage of gas hose shall be ventilated. The United States Occupational Safety and Health Administration (OSHA) incorporated NFPA 51B by reference at 29 CFR 1910.252. . 0000013825 00000 n 1926.1414 - Wire ropeselection and installation criteria. When this is impractical, fire resistant shields shall be provided. If continuous monitoring is not used, periodic monitoring is required. 1926.50 - Medical services and first aid. 1926.1205 (b) Before entry begins, the entry supervisor identified on the permit must sign the entry permit to authorize entry. 1926.30 - Shipbuilding and ship repairing. Nothing shall be placed on top of a manifold, when in use, which will damage the manifold or interfere with the quick closing of the valves. 1926.752 - Site layout, site-specific erection plan and construction sequence. 0000009020 00000 n 0000052163 00000 n Inform the controlling contractor of the permit space program that the entry employer will follow, including any hazards likely to be confronted or created in each permit space. Oregon OSHA provides a variety of publications, including; guide books, brochures, forms, hazard alerts, fact sheets, posters, cards, stickers, reports, and checklists on a variety of workplace health and safety topics. A Hot Work Permit is required whenever any hot work activity is conducted outside of an area designated for hot work. An OSHA "permit" is an employer-created and signed document that details the safeguards in place to protect an employee who's been assigned a particularly dangerous job function like working in a confined space, welding and cutting, or working on "live" electrical equipment. 0000065715 00000 n 1926.905 - Loading of explosives or blasting agents. Version Date Comments 5 March, 2012 Revised document 6 June, 2015 Update code citation - SFPC 2012 A. 1926.4 - Rules of practice for administrative adjudications for enforcement of safety and health standards. 1926.62 App A - Substance Data Sheet for Occupational Exposure to Lead, 1926.62 App B - Employee Standard Summary, 1926.62 App C - Medical Surveillance Guidelines.
-
osha hot work permit requirements 1926
Watch Osadia videos on YouTube and Vimeo; go on, see if YOU dare!
farmville va shooting 2021